Follow us on:

|
 |
AIRBORNE
FREQUENCY CONVERTER
|
|
AFC-7000-1-(50,
-60 or -400) AFC-7000-2-(50,
-60 or -400)
|
|
Behlman's
AFC-7000 is a ruggedly built, modified COTS frequency converter
designed to convert three-phase aircraft power to regulated
single-phase (115 or 230 VAC) 60 Hz ground power.
The AFC-7000 is ruggedly built to support aircraft takeoffs
and landings and designed to meet the input power requirements
of MIL-STD-704 and RTCA-DO-160.
In
the AFC-7000 you'll find the quality features you expect
from Behlman. Low output THD, high efficiency, plus excellent
line and load regulation.
There's
also a unique overload protection system that folds back voltage
to maintain rated current without output waveform distortion.
Units are supplied with RS-232 remote control and 28 VDC control
of Output On/Off. In addition the unit has provisions for slide
mounting.
Small
size, rugged construction, quiet operation and high efficiency
make the AFC-7000 ideal for use on aircraft to convert aircraft
power to ground power.
Features
-
Single
rack space (6U high)
-
Rugged construction
-
Unique
overload protection
-
Microprocessor
controller with Vacuum Fluorescent Display
-
RS-232
or 28VDC Output control
|
Click
here for printable
Specifications Sheet
| Specifications
|
|
INPUT
|
|
Voltage:
|
115/200VAC, +/-10%, 3-Ph, WYE, @ 30 Amps/phase max.
(power de-rated above 700HZ.
Multi Pulse
Input Transformer for Low Input Current THD
|
Frequency:
|
350-800
Hz
|
|
OUTPUT
|
|
Voltage:
|
7000-1:
115VAC, single-phase
7000-2:
230VAC, single-phase
|
Frequency:
|
50
Hz, 60 Hz or 400 Hz Accuracy: +/- 0.1 Hz
|
|
Power:
|
6900 VA
|
current:
|
60 Amps
@ 115 V
30 Amps
@ 230 V
|
|
Current Crest
Factor:
|
3:1
|
Line Regulation:
|
+/-0.1% for +/-10%
Line change
|
|
Distortion:
|
1.5%
THD typical, measured at full load, 115 Volts, 60 Hz
|
Load Regulation:
|
+/-0.7% No load
to full load
|
|
Efficiency:
|
80%
typical
|
Power Factor:
|
100% of rated output
into any power factor load
|
|
PROTECTIVE CIRCUITS
|
|
Input Protection:
|
Fast-acting
main circuit breaker with guard
|
Thermal Protection:
|
Internal temperature
sensor prevents heat damage
|
|
Constant Current
Mode:
|
Overload automatically
causes voltage foldback to provide maximum current without distorting
output waveform
|
Short Circuit
Protection:
|
Short circuit overload
electronically latches output open to protect load. Power restored
by recycling circuit breaker
|
|
CONTROLS / INDICATORS
|
|
Power On/Off
|
Circuit breaker
|
|
Control/Display
|
Microprocessor controller
with 24 characters X 2 lines Vacuum Fluorescent display. Displays
Volts, Frequency, current and Current limit. Fault indicator for Over Voltage
(OV), Over Current (OI), Over Temperature (OT), Constant Current
(CC) and Short Circuit (OL), Watts (W) and Power Factor (PF)
Set Current Limit (with RS-232 interface)
|
| Output
On/Off |
ON- with
Safety Interlock connector supplied with unit. ON/OFF- with customer
supplies 28VDC. ON/OFF- with RS-232 Interface. |
| Output
Indicator: |
Indicates
output relay is energized |
| Busy
Indicator: |
Indicated
a command is being processed by the microprocessor |
| Reset
Switch: |
Recessed
push-button switch to reset controller |
|
Remote Control:
|
RS-232 to monitor
unit, turn output On/Off and set current limit
|
|
MECHANICAL &
ENVIRONMENTAL
|
|
Dimensions:
|
High-strength
19" (48.3 cm) rack mount chassis, 10.5"H X 22"D (26.7 cm X 55.9
cm)
|
|
Weight:
|
128
lbs (58 kgs)
|
| Air
intake: |
Front
and Sides |
|
Cooling: |
Internal fans |
| Air
Exhaust: |
Rear |
| Input
Connections: |
J1
- P/N MS3102-24-10P |
|
Output Connections:
|
J2
- P/N MS3102-32-17S
|
| Control
Connections: |
J3
- P/N D38999-20WB35PN (Supplied with Safety Interlock plug) |
| Designed
to meet the conditions as defined in MIL-STD-810, Method 520.2
|
| Operating
Temperature: |
-4°
to 123° F (-20° to 50° C) |
| Storage
Temperature: |
-4°
to 140° F (-20° to 60° C) |
| Shock:
|
Designed
to meet, 18 impacts of 15G's for the duration of 11+/-1 millisecond. |
| Vibration:
|
Random
Vibration Frequency range of 20 to 1000Hz with Power spectrum
density of 0.04g²/Hz and from 1KHz to 2KHz beginning at 0.04g²/Hz
and drop at a linear -6db/octave rate. |
| Humidity:
|
0-95%
RH non-condensing. |
| Altitude:
|
Designed
to operate at altitudes of 10,000 feet. Can be exposed to 40,000
feet in a non-operating state, and operate normally when returned
to 10,000 feet or less. |
| Fungus:
|
Designed
not to afford fungus nutrition |
| Electromagnetic
Interference: |
Designed
to meet or exceed MIL-STD-461E requirements, intended for installation
on Aircraft. To meet RE102 requirement, shielded cable shall be
used for Input and Output Cabling. |
|
ELECTRICAL
CONNECTIONS:
|
|
J1
|
Power
Input Connector, P/N MS3102-24-10
|
|
J2
|
Power
Output Connector, P/N MS3102-32-17S
|
|
J3
|
Control
Connector, P/N D38999-20WB35PN (Supplied with Safety Interlock
plug)
|
|
MODEL
SELECTION
|
AFC-7000-1-60-S
(AFC-7000 with 115VAC, single-phase, 60 Hz output and optional
slides )
|
|
 |
 |