BL1350 AC POWER SUPPLY
FREQUENCY CONVERTER / INVERTER

1350VA, AC Power Supply / Frequency Converter / Inverter in a 3.5"H Chassis

BL1350

Frequency Converter, switch mode power supply, 1350VA at 1U high

 

Behlman's BL1350 AC Power Supply / Frequency Converter / Inverter, requires just 3.5" of rack

height, and weighs as low as 45 pounds, yet it delivers 1350 VA of quality AC power. In the BL 1350, you'll find the quality features you expect from Behlman, fully adjustable frequency and voltage, total harmonic distortion of less then 0.5%, high efficiency, plus excellent line and load regulation.

There's also a unique overload protection system that folds back the voltage to maintain maximum rated current without output wave form distortion and analog remote control. For rack mounted or bench top power, no AC source combines small size, high efficiency and low cost like the Behlman BL Series. 


Features

  • 1350VA in a 3.5" chassis, some models under 45 pounds

  • Parallelable for additional power or for 3 phase output

  • Unique overload protection prevents output distortion

  • Remote DC programming for voltage and frequency

  • True RMS readout of voltage and current

  • Low cost without compromising features or performance

Click here for printable Specifications Sheet

Specifications

INPUT

Voltage:

B-1 (115V), C-2 (115/230V +/-10%),

C-4 (120/208V, 3 phase, +/-10%)

Frequency:

47-63Hz 

 

BL1350pf: 85-270V 

 

47-63Hz

 

OUTPUT

Voltage:

0-135V or 0-270V

Other voltages available

Frequency:
45-500Hz (Optional 45-1000Hz)
 Power:
1350VA, Units can be stacked for increased power, or 2 or 3 phase output
 current:
10 Amps, 0-135V Range 
5 Amps, 0-270V Range
Current Crest Factor:
3:1
Line Regulation:
+/-0.1% for +/-10% Line change
Distortion:
0.5% THD Typical  (measured at full load, 100 Volts, 50Hz)
Load Regulation:
+/-0.7% No load to full load
Efficiency:
80% Typical
Power Factor:
100% of rated output into any power factor load

 

PROTECTIVE CIRCUITS

Input Protection:
Fast acting main circuit breaker
Thermal Protection:
Internal temperature sensor prevents heat damage
Constant Current Mode:
Overload automatically causes voltage foldback to provide maximum current without distorting output waveform
Short Circuit Protection:
Short circuit overload electronically latches output open to protect load. Power restored by recycling circuit breaker

 

CONTROL INPUTS

Voltage/Frequency:
0-10Vdc programming-voltage/frequency
External Synch:
Synchronizes AC output with external input
Optional:
IEEE488 or RS232 interface for remote programming and read back of output voltage and frequency

            

Front Panel Control

  • Power On/Off circuit breaker

  • Output On/Off toggle switch

  • Frequency and amplitude control (optional locking controls)

  • Digital readout (3.5 digits)-True RMS voltage/true RMS current/frequency

 

 

  • Range Switch (dual voltage range models)
  • Three LED's: Constant Current, Overload, OverTemp
  • Phase adjust
  • Three binding posts

MECHANICAL & ENVIRONMENTAL

Dimensions:
High strength 19" (48.3 cm) rack mounted chassis, 3.5" high by 22" deep (8.9 cm X 55.9 cm)
Weight:
BL1350B-1 & Pf 45 lb, C-2 & C-4 70 lb
Output Connections:
Front panel binding posts and rear mounted barrier strip
Operating Temperature:
32° to 131° F (0 to 55 degrees C)

 

MODEL SELECTION GUIDE

Model
Input Voltage
Output Voltage
Dual Range
Isolated Output
BL1350B-1(1)
115VAC

0 - 135VAC 
 0 - 270VAC 

Yes

 No
BL1350C-2(1)
115/230VAC

0 -135VAC 
 0 - 270VAC

Yes

Yes

BL1350C-4(1)

120/208VAC,

3 phases

0 -135VAC 
 0 - 270VAC

Yes

Yes

BL1350pf
85-270VAC

0 - 135VAC
0 - 270VAC

Yes

Yes

 

MODEL OPTIONS

Options
Description
E
Extended frequency range
L
Locking pots
T
Output: 0-150 or 0-300VAC
T2 Output: 0-34 or 0-135 VAC
S
Slides
B
Rubber Feet
A
Safety Sockets
I
IEEE-488 interface
IR
RS232 interface
R Ruggedization
Motor Test
J
Input: 100/200VAC single phase
H
Cabinet enclosure for 3 units
P
Parallel wiring for 2 or 3 phases
W Wiring for 3 phase configuration

Note:1: 

Available models with motor testing option add -MT (See below).

Contact factory for additional options. 

Please note that Option MT includes all of the specifications of the standard BL Series plus the following to features to meet the requirements for motor testing:

  • Unique overload protection prevents output distortion
  • "Soft Start" allows starting motors in "locked rotor" condition by folding back the voltage and slowly increasing it as the motor starts to accelerate.
  • Capable of starting motors which normally require 140Amps locked rotor starting currents.
  • Capable of supplying a running current up to 14 Amps at 50% duty cycle.

 

West Coast

2363 Teller Road / Suite 108,
Newbury Park, CA 91320
TEL (800) 456-2006 - (805) 375-7046
FAX (805) 498-2147

Headquarters:

80 Cabot Court.,
Hauppauge, NY 11788
TEL (800) 874-6727 - (631) 435-0410
FAX (631) 951-4341 * E-mail: sales@behlman.com

Easy Payment, We accept:
MasterCard, Visa,
American Express

About Behlman | Select a Product | Catalog Request | Support | GSA | Sales/Reps | Orbit Int'l | Home
AC Power Supply/Frequency Converter: Switching | Inverters | UPS | Modified Standard Products
COTS: AC-DCDC-DC | Railroad Signal Source | Application Notes | Wild Frequency Information Center