Follow us on:

|
 |
INVERTER DC
- AC Converter - Sine Wave output
Utility power - On-Line Power - Standby Power
|
INV-2500
DC/AC Inverter,
produces AC Power from your DC source or Battery bank
|
|
|
Behlman's
INV series, INVERTERS deliver 2500 VA of 120 Vac,
60 Hz power in a 7". high rack mount chassis. The Inverters
operate from either 48 Vdc or125 Vdc VDC. You have a choice of
a low distortion, sinewave output, Model INV2500.
|
|
FEATURES
-
2500
VA in a 7" high chassis
-
Sinewave
Output, Isolated and Floating
-
100% of Rated
Power into any Power Factor Load.
-
-
Excellent Line
& Load Regulation
-
Custom
output frequencies for frequency converter / frequency conversion
applications (consult factory).
-
Option Bypass, DC to AC with Alarms and Indicators or AC to DC.
|
Click
here for PrintableSpecifications
Sheet.
|
SPECIFICATIONS
|
|
INPUT
|
|
MODELS
|
|
|
| INPUT |
48 VDC +/-
20% |
125 VDC +/- 20%
|
| |
-
Quiescent
DC current drain less than: 5 Amps @ 48 VDC,
3 Amp @ 125 VDC,
-
Maximum
DC burden (full load):
80 Amps DC @ 40 VDC,
30 Amps DC @ 100 VDC,
-
Connections:
Barrier type terminals on the rear.
|
|
OUTPUT
|
|
Voltage:
|
120 VAC +/- 5%,
60 Hz isolated
|
|
Current:
|
21 Amps
|
|
Power:
|
2500VA
|
|
Waveform:
|
Sine Wave Output
|
|
Power Factor:
|
100% of rated output
into any power factor load.
|
|
Distortion:
|
< 3% THD typical
|
|
Efficiency:
|
80-85%
typical
|
|
Connection:
|
Barrier type terminals
on the rear
|
|
PROTECTION CIRCUITS
|
|
Input:
|
Main circuit breaker
|
|
Short Circuit
Protection:
|
Short circuit overload
electronically latches output to protect load.Power
restored by cycling input power
|
|
Thermal Protection:
|
Internal temperature
sensor prevents heat damage.
|
|
FRONT
PANEL CONTROLS and INDICATORS
|
|
Power On/Off circuit
breaker
|
| Three LED's:
DC IN, AC IN, AC OUT . ( With Option D1 or A1 ) |
|
Bypass fuse: 30
Amps
|
|
MECHANICAL SPECIFICATIONS
|
|
Dimensions:
|
High strength table
top chassis with rack-mount kit, 7"H x 17.00"W x 19.0"D.
|
|
Weight:
|
35 lbs
|
|
ENVIRONMENT SPECIFICATIONS
|
|
Operating Temperature:
|
-20 to 55 C.
|
|
Humidity:
|
Up to 95% non-condensing
|
|
SWC:
|
Designed to meet
IEEE C37.90.1.
|
|
Fast Transient:
|
Designed to meet
IEEE C37.90.1.
|
|
EMI:
|
Designed for immunity
to conducted & radiated EMI.
|
|
RFI:
|
Designed to meet
IEEE C37.90.2 - 1997.
|
|
OPTIONS
|
|
D1
|
AC Input, with Indicators
and Alarms.
DC input primary. Includes AC input with "Transfer Circuit"
to switch from DC input to AC input, in 300msec. typical, upon
loss of DC input or Inverter. Includes AC fuse, (3) indicators
and (3) form "C" contacts for AC IN, DC IN and Inverter
ON.
|
|
A1
|
Same as Option D1
except AC Mains is primary input with "Transfer" to
DC input upon loss of AC.
|
|
 |
 |