AC
POWER SUPPLY / FREQUENCY CONVERTER
• Switching
• Linear
INVERTER
UNINTERRUPTIBLE POWER SUPPLY (UPS)
MODIFIED STANDARD PRODUCTS
COTS CUSTOM POWER SUPPLY
• AC-DC
• DC-DC
RAILROAD SIGNAL SOURCE
NEW PRODUCTS
APPLICATION NOTES
WILD FREQUENCY INFORMATION CENTER
|
 |
Modified
Standard Products
Many of our customers need something that's not in anyone's
catalog.
Below are some examples of what Behlman has modified
and produced to provide
solutions for our customers' requirement.
--- Quick - Click Jump Down---
<>
<> <>
<>
Once below, click
on the model name/number or a picture to go to a more detailed data
sheet with listed
options.
AC Power Supplies and Frequency Converters
(Click on the model number or part number to see
a PDF of the full specification)
|
AC
Frequency Converter, 10,000VA.
Environmentally sealed in a stainless steel cabinet for use
in an unsheltered environment.
Input: 120/208 Vac, 3 phase 360 – 440 Hz.
Output: 120/208 Vac, 3 phase @ 28A/phase, 60Hz.
|
|
AC
Power Source for Oil Exploration tools, 1500VA. 0 - 720Vac output,
master -slave capability for higher power. RS485 remote control.
|
 |
Rail
Road Signal Source, 1200VA. 60Hz in - 100Hz out,
Isolated Output, with alarm contacts and indicators.
|
 |
|
|
|
Rail
Road Signal Source, 3,000VA.
Input and Output Isolated.
Short circuit protection with auto restart.
Input: 120 Vac, Single Phase, 57 - 253 Hz.
Output: 120 Vac, Single Phase, 25A, 100Hz.
External Sync
Alarms-contact closures & indicators
|
 |
Rail
Road Signal Source, 5,000VA.
Input and Output Isolated.
Short circuit protection with auto restart.
Input: 120 Vac, Single Phase, 57 - 63 Hz.
Output: 120 Vac, Single Phase, 42A, 100Hz.
External Sync
Alarms-contact closures & indicators
|
 |
|
|
|
Rail
Road Signal Source, 5,000VA,
Isolated Input and Output.
Short circuit protection with auto restart.
Mounted in a 12U Cabinet.
AAR Terminals for input and output connections.
Input: 480Vac 60Hz Single Phase
Output: 480Vac 100Hz Single Phase
External Sync
Alarms-contact closures & indicators
|
 |
AC
Frequency Converter, 5,000VA.
Used in production for hydraulic test stands.
Microprocessor controller with 24 characters X 2 lines Vacuum
Fluorescent display.
RS232 remote control.
Input :380 Vac, 3 phase or 460 Vac, 3 phase (jumper selectable),
47 – 63 Hz.
Output: 0-135Vac 1 Phase/40A or 3 Phase/12.5A per phase, 45
- 500Hz.
|
 |
AC
Frequency Converter, 7,000VA.
Used in production for motor / appliance testing
Microprocessor controller with 24 characters X 2 lines Vacuum
Fluorescent display.
Input: 120/208 Vac, 3 Ph WYE/Delta, 47-63 Hz
Output: 0-230 Vac, L-N, 1 Phase @ 32A, 45 - 500Hz
|
 |
|
|
|
AC
Frequency Converter, 7,000VA.
High Shock, on board aircraft - military test system.
Microprocessor controller with 24 characters X 2 lines Vacuum
Fluorescent display.
Input: 115/200 Vac, 3 pH WYE/Delta, 400 Hz, @ 30A / phase max.
Output: 115Vac, 1 Phase, 60Hz
|
 |
AC
Power Supply, 1350VA.
Oil Research and Exploration.
Input: 115Vac, 60 Hz from truck generator.
Output: High voltage 60Hz, low noise.
Computer controlled via IEEE-488.
Custom Front Panel controls.
|
 |
AC
Frequency Converter, 3000VA and 5000VA.
Two Behlman units custom installed into one rack.
Built for NETE , Naval Engineering Test Establishment of Canada.
Motor testing application.
Input: 120/208 Vac, 3 Ph WYE/Delta, 47-63 Hz
Output: 2 outputs, 3kVA and 5kVA, 0-135Vac and 0-270Vac, 45 -
1000Hz.
|
 |
|
|
|
AC Current source, 15,000VA.
Current source for testing of circuit breakers.
Input: 120/208 Vac, 3 Ph WYE/Delta, 47-63 Hz
Output: 5Vac @ 3,000Amps, 45 - 500Hz.
3 x 5kVA sources in parallel for a 15kVA total.
Custom Front Panel controls.
|
 |
|
|
|
|
Rugged Uninterruptible Power Supplies / Ruggedized UPS
(Click on the model number or part number to see
a PDF of the full specification)
|
|
Double
Conversion, High Shock (Navy ship board application), 12 Inch
Deep Rack Mount UPS, with Power Factor Correction. High Rate batteries
for extended run time. Has optional shallow depth battery racks
for extended run time or for additional power for same run time.
|
|
|
High
Temperature Model with Frequency Conversion.
The UPS is mounted in a system's shock cabinet. System is installed
on military HMMWVs.
|
 |
|
Double
Conversion, Global On-Line, Rack Mount UPS with Frequency Conversion,
Power Factor Correction, High Rate Batteries for extended run
time and optional external battery rack for additional run time.
|
 |
|
Double
Conversion, High Shock ( Navy ship board application) On-Line,
Rack Mount UPS, Dual AC Input power, MIL-STD-1399, Power Factor
Correction. Extensive communication and Remote control features.
External battery back in rack mount chassis for easy replacement
and optimum size.
|
 |
|
|
|
|
 |
 |