FREQUENCY CONVERTER - AC POWER SUPPLY

PF1351
World Wide AC Power Supply / Frequency Converter / Inverter on your bench or test rack

P1351 Ac Power Supply


Behlman's  PF1351 AC Power Supply / Frequency Converter / Inverter, delivers 1350VA of clean, regulated AC power in a 3.5" high bench top unit, that easily converts to rack mount, for far less cost than competitive models. 
The PF1351 can simulate any world wide utility as well as aircraft and shipboard power. The unit can be controlled from the front panel or remotely using the optional 0-10 VDC, RS232 or IEEE-488 interface. Other options include extended frequency range, 45 Hz to 1000 Hz and rack mount kit.  
The PF1351 delivers all the quality features you have come to expect from Behlman; clean sinewave output with excellent line and load regulation, high efficiency and low harmonic distortion, in the industries most compact size

 

Adobe Acrobat
Specifications
Power:

95-270 VAC, @ 16Amps Max. (Full power from 115VAC to 270 VAC)

 

Input

Voltage:
120, +/-10%
Frequency::

 

47-63 Hz. 47-440Hz (Non CE Mark)
 

Output

Voltage:
Dual Range; 0 - 135 & 0 -270VAC, full isolation from input.  
Frequency:
50Hz, 60Hz or 400Hz
Crest Factor:
3:1
Power Factor:
100% of rated output into any power factor load.
Distortion:
1% TypicalTHD (measured at full load, 115VAC, 60hZ.
AC Regulation:
0.7% @ F.S., No Load to Full load, resistive
Line Regulation:
+/-0.1% for +/-10% line change
AC Regulation Response time: 250 – 300 msec. typical

 

Controls / Indicators 

Power On/Off:
Rocker type switch
Display:
Two DMM’s, one for volts and the other Freq/Amps
Output On/Off:
Push button switch 
Range:
Push button switch (High/Low)
Indicators:
Output on, high range, frequency or amps, constant current and fault

Protective Circuits

Input Protection:
Fuse.
Constant Current:
Overload automatically causes voltage fold-back to provide maximum current without distorting output waveform
Short Circuit Protection:
Short circuit overload electronically latches output open to protect load... power restored by recycling input power.
Thermal Protection:
Internal temperature sensor prevents heat damage.
Front Panel Display
  • Power on/off switch

  • Frequency Select Switch

  • Range switch

  • Volts potentiometer

  • Meter for Volts readout

  • Fault indicator

Mechanical Specifications

Chassis:
High strength bench top chassis
Dimensions:
3.5”H x 17”W x 22”D
Weight: 49lbs
Operating Temperature:
0 Deg C to +55 Deg C
Input Connector:
IEC320 C-20 receptacle with six foot line cord with NEMA 5-15 plug
Output Connection:
European "Schuko" receptacle with NEMA 5-15 adapter. (1)

Supplied with North American line cord with NEMA 5-15 Plug.

(1) Other Adapters Available


Options

A:
Analog remote control, 0-10 VDC for volts and frequency and contact closure for range and output
E:
Extended frequency range, 45-1000 Hz
L:
Locking pot
RM:
Rack Mounting Kit
RO:
Rear Output NEMA 5-15 receptacle
TB: Rear output enclosed terminal block

Certifications

CE MARK

West Coast

2363 Teller Road / Suite 108,
Newbury Park, CA 91320
TEL (800) 456-2006 - (805) 375-7046
FAX (805) 498-2147

Headquarters:

80 Cabot Court.,
Hauppauge, NY 11788
TEL (800) 874-6727 - (631) 435-0410
FAX (631) 951-4341 * E-mail: sales@behlman.com

Easy Payment, We accept:
MasterCard, Visa, Discover,
American Express

About Behlman | Select a Product | Catalog Request | Support | GSA | Sales/Reps | Orbit Int'l | Home
AC Power Supply/Frequency Converter: Switching | Inverters | UPS | Modified Standard Products
COTS: AC-DCDC-DC | Railroad Signal Source | Application Notes | Wild Frequency Information Center