AC
POWER SUPPLY / FREQUENCY CONVERTER
• Switching
• Linear
INVERTER
UNINTERRUPTIBLE POWER SUPPLY (UPS)
MODIFIED STANDARD PRODUCTS
COTS CUSTOM POWER SUPPLY
• AC-DC
• DC-DC
RAILROAD SIGNAL SOURCE
NEW PRODUCTS
APPLICATION NOTES
WILD FREQUENCY INFORMATION CENTER
|
 |
INVERTER DC
- AC Power Supply
|
SQ300-XXX
DC
- AC SQUARE WAVE INVERTER FOR RAILROAD AND TRANSIT
|
|
|
Behlman's
SQ300 series, Behlman's SQ300 Series is a rugged inverter
that supplies 120 VAC from a 12 VDC source for continuous operation
or standby operation of railroad signal equipment. The input is
from a nominal 13.2 V lead acid or nickel cadmium battery, which
should have a low internal impedance. The output is a square wave
with a fixed frequency, 60 Hz, 100 Hz or 250 Hz, +/- 1% regardless
of load, input voltage or temperature.
|
|
FEATURES
-
SHELF OR PLUG-BOARD MOUNT
-
HIGH OVERLOAD CAPACITY
-
BUILT-IN SURGE PROTECTION
-
CONSTANT FREQUENCY
-
CONFORMS TO AAR RECOMMENDED PRACTICES
|
Click
here for Printable Specifications Sheet.
|
SPECIFICATIONS
|
|
INPUT
|
|
MODELS
|
|
|
SQ300-250
|
| INPUT |
12 VDC +/-
20% |
12VDC +/- 20%
|
12 VDC +/-
20% |
|
Output
Frequency |
60HZ
|
100HZ |
250HZ |
|
OUTPUT
|
|
Voltage:
|
120 VAC +/- 5%
Isolated and Floating. Proportional to Input Voltage
|
|
Current:
|
2.5 Amps
|
|
Power:
|
300VA
|
|
Waveform:
|
Square wave
|
|
Efficiency:
|
90% typical at
full load
|
|
Connection:
|
AAR
terminals
|
|
PROTECTION CIRCUITS
|
|
Input:
|
Fuse with surge
arrestor and lightning protection
|
|
Overload:
|
Overload
fault current, electronically limited to protect load.
|
|
Thermal Protection:
|
Internal temperature
sensor prevents heat damage.
|
|
MECHANICAL SPECIFICATIONS
|
|
Dimensions:
|
High-strength shelf-mount
chassis with optional plug-board
mount, 5”W X 8”H X 9.5”D
|
|
Weight:
|
25 lbs
|
|
ENVIRONMENT SPECIFICATIONS
|
|
Operating Temperature:
|
-40 to 71 C.
|
|
Humidity:
|
Up to 95% non-condensing
|
|
OPTIONS
|
|
PB
|
Standard
Plug-Board mount with two tabs at top and bottom
|
|
 |
 |