Products

Ground / Mobile

COTS (Commercial Off The Shelf) DC-DC, AC-DC Power Supply

COTS AC-DC and DC-DC power sources designed for Mil, Military, Industrial, Commercial, Ground / Mobile applications.With over 60 years experience in the design and manufacture of critical electronic equipment in its "World Class" facility, Behlman is a key resource for precision COTS power supplies. Behlman produces COTS power supplies for military, industrial and commercial applications. Innovative engineering skills allow Behlman to tailor its wide range of designs to specific customer requirements. Behlman can produce new designs, Form-Fit-Function replacement and modernize old or obsolete power supplies. Behlman can reduce your cost and shorten delivery by using COTS power supplies.

All Behlman COTS power supplies are ruggedly built and designed to meet the rigors of high end industrial and military applications on aircraft, shipboard, ground or mobile platforms.

COTS (Commercial Off The Shelf) DC-DC, AC-DC Power Supply
Ground and Mobile COTS Power Supplies
Model No. / Part No Power (W) Output Volts Output Current Amps Cooling Input Voltage Dimensions
HPRU1000Q-6-EC-5693 / 84074 883 4 outputs 4.2 to 80 Convection 115/200 VAC, 3 ø 47-440 Hz (3U) 5 ¼”H x 5 ¼”W x15”D
DCL150S-1-(0-5V,2) / 94019-5 600 12 50 Convection 85-265 VAC, 47-440 Hz 9.13”W X 8.0”D X 2.0”H
DCS200S-1-(24,12.5) / 94043 240 24 12.5 Conduction 85-265 VAC, 47-440 Hz 8.75"L X 5.0"W X 1.18"H
DCS125 (6)-3X-5449 / 94047 125 6 outputs 0.8 to 15 Conduction 28 VDC 6.0"L X 3.5"W X 1.5"H
VME4000(8)-1-... / 94028 600 8 outputs 0.2 to 50 Convection 85-265 VAC, 47-440 Hz Per dwg package 24046
DCS2000S-1-(28,54) 94107 Spec. Sheet 2000 28 54 Conduction 85-265 VAC, 47-440 Hz, Power Factor Corrected 13.97"L X 8.0"W X 2.0"H
DCR2U- (Watts)- Input- (V, A) 2000, 3000 or 4000 3.3 - 48 Voltage and power dependent Convection Single or three phase AC, or 200-400VDC 3.5” H x 17” W x 18
Airborne COTS Power Supplies
Model No. / Part No Power (W) Output Volts Output Current Amps Cooling Input Voltage Dimensions
DCM1000(8)-6-(5,20).../ 00389-2 1000 8 outputs 1.7 to 20 Conduction 115/200 VAC, 3ø, 400Hz 12.00"L X 7.00"W X 2.38"H
DCS200T-2-(5, 5).../ 93015-2 260 3 outputs 4.75 to 12 Conduction 90-132 or 180-264 VAC, 47-440 Hz 7.75"L X 5.0"W X 1.15"H
VME700Q-1-(5,80) /.94018-7 700 4 outputs 0.8 to 80 Convection 85-265 VAC, 47-440 Hz 9.13”W X 8.0”D X 2.0”H
DCL150D-1-(5,1.25).../ 94019-3 20 - 150 2 outputs 1.25 Conduction 115 VAC +/- 20%, 360-440 Hz 4.87"L X 3.52"W X .84"H; +/- .02”
DCM500T-6-(5,77) / 94026 460 3 outputs 0.5 to 77 Conduction 115/200 VAC +/- 20%, 360-440 Hz 13.00"L X 7.00"W X 2.95"H
DCS200-6-6283 / 94030-1 200 7 outputs 0.5 to 20 Conduction 115/200 VAC +/- 20%, 360-420 Hz 4.83 L X 3.61 W X 4.24 H
cPCI 6005(5)-1...... / 94045 600 5 outputs 2 to 60 Convection 85-265 VAC, 47-440 Hz 9.13”W X 8.0”D X 2.0”H
UAV-6284 / 94050 100 5 outputs 0.08 to 4 Single Brd 16-32VDC N/A
DCS200S-6-(82.5,2.42) / 94055 200 1 outputs 2.4 Conduction 115/200 VAC, 3ø, 400Hz 7.75"L X 5.0"W X 1.15"H
DCS1000S-6-(60,16.7) / 94056 1000 1 outputs 16.7 Conduction 115/200 VAC, 3ø, 400Hz 9.75"L X 5.0"W X 2.25"H
DMCA4000(5)-6.../ 94057 4000 5 outputs 12.5 to 167 Convection 115/200 VAC, 3ø, 400Hz 4.5”H x 16”W x 21.5
DCR2U-2000D-6-(28, 71)-(12, 21) / 94094 2250 28 & 12 71 & 33.3 Convection 115/200 VAC, 3-phase, 360-440 Hz, IAW MIL-STD-704F 3.5” H x 17” W x 18" D
94094-1 /DCR2U-4000D-6-(24, 83.3)-(24, 16.7) 4400 48 & 24 83.3 & 16.7 Convection 115/200 VAC, 3-phase, 360-440 Hz, IAW MIL-STD-704F 3.5” H x 17” W x 18" D
DCS2000S-1-(28,54) 94107 Spec. Sheet 2000 28 54 Conduction 85-265 VAC, 47-440 Hz, Power Factor Corrected 13.97"L X 8.0"W X 2.0"H
DCR2U- (Watts)- Input- (V, A) 2000,3000 or 4000 3.3 - 48 Voltage and power dependent Convection Single or three phase AC, or 200-400VDC 3.5” H x 17” W x 18"D
Shipboard COTS Power Supplies
Model No. / Part No Power (W) Output Volts Output Current Amps Cooling Input Voltage Dimensions
405260-903 530 8 outputs 0.5 to 45 Convection 115/200 VAC +/- 20%, 360-440 Hz 11.5"L X 8.75"W X 4.0"H
405260-920 515 7 outputs 0.5 to 45 Convection 115/200 VAC +/- 20%, 360-440 Hz 11.5"L X 8.75"W X 4.0"H
HPRU1000Q-1-6285 / 94016 800 4 outputs 4.5 to 80 Convection 120 VAC, +/- 10%, 1 ø 1/3 Rack Mount Chassis, (3U) 5 ¼”H x 15”D) with guide pins bushings.
CCRT25Q-3-6286 / 94020 30 25000 1.2 milliamps Conduction 28 Volts DC ±2% 8.0"L X 6.0"W X 2.75"H
DCS200(5)-2-(26,0.2).../ 94024-1 200 5 outputs 0.2 to 2 Conduction Dual input range, 1 ø 8.0"L X 5.0"W X 1.1"H
DCA2000S-2-28,72 / 94036 2000 28 72 Convection 115 VAC, 3 ø Delta, 47-440 Hz 5.0” H, 8.0” W, 14” D
DCA2000S-2-60,34 / 94037 2000 60 34 Convection 115 VAC, 3 ø Delta, 47-440 Hz 5.0” H, 8.0” W, 14” D
DCS2000D-1-(5,120).../ 94038 2000 2 outputs 120 to 160 Conduction 85-265 VAC, 47-440 Hz 14"L X 8.0"W X 2.0"H
DCS1000T-1-(-12,3.5).../ 94039 500 3 outputs 3.5 to 16.7 Conduction 85-265 VAC, 47-440 Hz 11.32"L X 5"W X 2.0"H
DCS1000T-1-(-12,3.5).../ 94039-1 1000 3 outputs 6.25 to 16.7 Conduction 85-265 VAC, 47-440 Hz 11.32"L X 5"W X 2.0"H
DCS2000T-1-(12,25).../ 94040 2000 3 outputs 3 outputs @ 25 each Conduction 85-265 VAC, 47-440 Hz 2.0” H x 8.0” W x 13.97” D
DCS1000D-1-(56,11).../ 94041 1000 2 outputs 6 to 11 Conduction 85-265 VAC, 47-440 Hz 2.0” H x 5.0” W x 11.32” D
DCFX1000D-1-(24,45).../ 94042 1000 2 outputs 15 to 45 Convection 85-265 VAC, 47-440 Hz 11.22"L X 10.63"W X 4.68"H (over heat sink and connectors)
VME4000(8)-1-... / 94044 600 8 outputs 0.2 to 50 Convection 85-265 VAC, 47-440 Hz Per dwg package 24069
DCM2000(6)-6280 / 94087 2000 6 outputs 4 to 12 Convection 115/200 VAC, 400 Hz, 3-phase 8.0” H x 16.0” W x 16” D
DCS1000D - 8 - (15, 33.3)- (15, 33.3) / 94088 1000 15,15 33.3,33.3 Conduction 115 VAC, 3-phase Delta, 360-440 Hz 9.75"L X 5.0"W X 2.50"H
DCS1000D-1-(12, 50) (28, 10.7).../94093 1000 2 outputs 10.7 & 50 Conduction 85-265 VAC, 47-440 Hz 11.32"L X 5"W X 2.0"H
DCR2U- (Watts)- Input- (V, A) 2000,3000 or 4000 3.3 - 48 Voltage and power dependent Convection Single or three phase AC, or 200-400VDC 3.5” H x 17” W x 18
DCS2000S-1-(28,54) 94107 Spec. Sheet 2000 28 54 Conduction 85-265 VAC, 47-440 Hz, Power Factor Corrected 13.97"L X 8.0"W X 2.0"H
Industrial COTS Power Supplies
Model No. / Part No Power (W) Output Volts Output Current Amps Cooling Input Voltage Dimensions
SCI-890Q-2 / 94048 550 4 outputs 1.5 to 100 Convection 90-240 VAC, 1ø 47-63 Hz 19”W X 5 ¼”H x 19.5”D
HPRU1000D-1-6287 / 94051 550 4 outputs 1.5 to 100 Convection 90-240 VAC, 1ø 47-63 Hz 6.3”W X 5 ¼”H x 19.5”D
4510225B 384 32 VDC 12 Convection 18 -45 VDC N/A
DCR2U- (Watts)- Input- (V, A) 2000, 3000 or 4000 3.3 to 48 Voltage and power dependent Convection Single or three phase AC, or 200-400VDC 3.5” H x 17” W x 18
  • Wide input range
  • Compact size
  • Protection circuits
  • High efficiency
  • Conduction, convection or forced air cooling

Behlman’s COTS airborne, shipboard, ground and mobile Power Supplies are available in a wide range of power from 150 watts to 4000 watts. Inputs are wide range DC or any single or three-phase mains power or aircraft power. The COTS power supplies are highly reliable, rugged, switch mode units built for high-end industrial and military applications. Some available features include N+1 redundancy, hot-swappable, parallelable, single and multi-outputs outputs, overvoltage, over current and over temperature protection and supervisory circuits and alarms.

High reliability, compact size, rugged construction and high efficiency make Behlman’s COTS power supplies the best choice for critical applications.

Rugged, reliable and easy to use for a variety of applications:

  • Airborne power for server, disc drive, work station and receiver/transmitter
  • Shipboard power for fire control, displays, motion systems and communications
  • Ground power for radar, test sets, shelters
  • Mobile power for vehicles and launch systems

INPUT                                       Wide range DC or Single-or three-phase AC

 

OUTPUT          

Power:                                       150 watts to 4,000 watts

Voltage:                                     See individual specifications

Current:                                     See individual specifications

Line Regulation:                         See individual specifications

Load Regulation:                        See individual specifications

PARD Ripple & Noise:                See individual specifications

Efficiency:                                   80% - 90% typical

 

PROTECTIVE CIRCUITS

Over Voltage:                              See individual specifications 

Over Current:                             See individual specifications

Over Temperature:                     See individual specifications

 

CONTROLS / INDICATORS         See individual specifications

 

MECHANICAL & ENVIRONMENTAL     See individual specifications

Dimensions:                                             See individual specifications

Weight:                                                    See individual specifications

Cooling:                                                  See individual specifications

Operating Temperature:                           See individual specifications

Storage Temperature:                              See individual specifications

Headquarters

  • Address : 80 Cabot Court, Hauppauge, NY 11788
  • Tel : (631) 435-0410
  • US : (800) 874-6727
  • Fax : (631) 951-4341
  • E-mail : sales@behlman.com
  • VP-XTRA
  • follow us :
  • usa flag
    Proudly Made In The U.S.A
  • Easy Payment:
    american express
    visa card
    master card
© 2024 BEHLMAN ELECTRONICS, INC. All rights reserved. Website created by Dotlogics