Behlman’s Railroad AC signal sources are a ruggedly built, modified COTS frequency converter, designed to convert ground power to regulated single-phase signal sources used to provide isolated signal frequencies. All Behlman Railroad Power Supplies, Inverters and DC-DC converters are ruggedly built, modified COTS units designed to support the rigorous environmental conditions in bungalows, adjacent to railroad tracks.
In the Railroad series you’ll find the quality features you expect from Behlman, rugged construction, low output THD, high efficiency, Input and output isolation, auto reset, AAR terminals plus excellent line and load regulation.
Model | Power (VA) | Output Volts VAC (RMS) | Output Current (Amps) | Frequency (Hz) | Input Volts 1Ø VAC | Dimensions (19” Rack-Mount) |
---|---|---|---|---|---|---|
RR1200 | 1200 | 120 | 10 | 50, 60, 83, 91.66, 100, 200, 250 | 120, 1ø | 3.5”H x 17”D |
RR2000 | 2000 | N/A | N/A | N/A | N/A | N/A |
BL1200 | 1200 | 120 | 10 | 100 | 120, 1ø | N/A |
BL3100 | 3000 | 120 | 25 | 100, 200 or 250 | 120/230, 1ø | 7.0”H + 7.0 |
BL3200-C-1-91.66-RR | 3000 | 240 | 12.5 | 91.66 | 120/208 VAC, 3ø | 3.5”H + 7.0 |
BL5100 | 5000 | 120 | 37 | 100, 200 or 250 | 120/230, 1ø | 28.3”H x 31.6”D x 22.1”W cabinet with casters |
BL9200 | 9000 | 120 | 75 | 100, 200 or 250 | 240, 1ø | 44”H x 31.6”D x 22.1”W cabinet with casters |
BL12000 | 12000 | 240 | 50 | 100, 200 or 250 | 240, 1ø | 44”H x 31.6”D x 22.1”W cabinet with casters |
BL+20-1-C1-480-25-RR5212 | 20000 | 480 | 42 | 25 | 480Vac, 3 ø, 60Hz | Main Cabinet: 68.3 |
BL30-1-H-130-F025RR | 30000 | 270 | 112 | 25 or 100 | 480 VAC, 1ø | 68.3 |
TM5000120-100 | 5000 | 120 | N/A | 100 | 120 | 17 |
TM30-600-F025-6079 | 30000 | 480 | N/A | 25 or 100 | 480 | 42”H x 27.1”W x 36.4”D |
Model | Power (VA) | Output Volts VAC (RMS) | Output Current (Amps) | Frequency (Hz) | Input Voltage (VAC) | Dimensions (19” Rack-Mount) |
---|---|---|---|---|---|---|
ACDC-1200-125-TB-5292 | 1200 | 120 | 10 | 100 | 120, 1ø 47-250 Hz or 250VDC | 5.25 |
S600 – 112 - 5099 | 600 | 120 | 5 | 100 | 120 VAC or 12 VDC | 3.5 |
SQ300 | 300 | 120 +/-5% | 2.5 | 50, 60, 100, 200 or 250 | 12VDC | 8.00 |
4510225B | 384 Watts | 32 VDC | 12 | N/A | 18 – 45 VDC | Per outline drawing: 240-013-000 |
Behlman has a complete line of Rail Road signal sources, which are available with the following features:
Behlman’s RR series of Railroad Signal Sources and Frequency Converters are low cost, highly reliable, switch mode units built for Railroad Signaling. The RR series can be supplied with any single or three-phase input and outputs a clean, regulated AC signal at a precise frequency from 25 Hz to 250 Hz. These signal sources are built to support the rigors of operating in the harsh environment of Railroad signaling equipment.
In the Railroad series you’ll find the quality features you expect from Behlman, rugged construction, low output THD, high efficiency, Input and output isolation, auto reset, AAR terminals plus excellent line and load regulation.
INPUT
Voltage: AC or DC (Contact factory with your requirement)
Frequency: 47-253 Hz
OUTPUT
Power: 1200 VA to 30 KVA
Voltage: 120 to 480 VAC, isolated
Frequency: 50 Hz, 60 Hz, 100 Hz, 200 Hz, 250 Hz
Current: 10 Amps to 132 Amps per phase
Crest Factor: 3:1
Power Factor: 100% of rated output into any power factor load
Distortion: 1.5% to 3% THD typical, measured at full load
Line Regulation: +/- 0.7% for +/- 10% line change
Load Regulation: +/- 0.7%, no load to full load
Efficiency: 80% typical
PROTECTIVE CIRCUITS / INDICATORS
Input: Main circuit breaker and surge arrestors.
Constant Current Mode: Overload automatically causes voltage fold-back to provide
maximum current without distorting output waveform
Overload Protection: Short Circuit overload electronically disables output to protect load.
Automatic reset upon overload removal.
Thermal Protection: Internal temperature sensor prevents heat damage.
Output: Surge arrestors.
Meters: Digital Meters for Volts, Amps & Frequency.
OPTIONS:
A: Alarms, Contact closure & Indicator
1. Inv OK - Loss of Inverter output.
2. Sync - Loss of sync input
3. Lock - Out of phase condition between Inverter output and Sync Input
4. Over Temp - Over Temperature
AAR: AAR Terminals, input and output
ID: Input Turn on Delay
21-00: High strength Rack Cabinet with casters 30”H x 31.6”D x 22.1”W.